Audi 100/A6

1990-1997 of release

Repair and car operation



Audi 100/A6
+ 1. The maintenance instruction
+ 2. Maintenance service
- 3. Engines
   + 3.1.1.2. Technical characteristics
   + 3.1.2. 5-cylinder engines
   - 3.1.3. 6-cylinder engines
      3.1.3.2. A gear belt
      3.1.3.3. A head of cylinders
      3.1.3.4. Valves
      3.1.3.5. Replacement маслосъемных caps of valves
      3.1.3.6. Check of directing valves
      3.1.3.7. Fair processing of a landing facet of a saddle / the valve
      3.1.3.8. Grinding in of saddles of valves
      3.1.3.9. Compression check
      3.1.3.10. A poliklinovoj belt
      3.1.3.11. Greasing system
      3.1.3.12. The oil pump
+ 3.2. Diesel engines
+ 3.3. Removal and a partition of engines
+ 4. Cooling system
+ 5. Heating and ventilation
+ 6. Fuel system
+ 7. An exhaust system
+ 8. Systems of start, ignition
+ 9. Transmission
+ 10. Brake system
+ 11. Suspension brackets, a steering
+ 12. A body
+ 13. An electric equipment
+ 14. A good advice


3.1.3.12. The oil pump

Removal

PERFORMANCE ORDER
1. The oil pump is in front of the block of cylinders and is resulted from a cranked shaft.
2. Remove поликлиновый a belt.
3. Remove a gear belt.
The prevention

After that a cranked shaft and a camshaft any more do not turn.


4. Remove the bottom and top parts of the oil pallet.
5. Turn away a tension roller of a gear belt.
6. Turn away directing roller of a gear belt.
7. Turn out a carving stopper on the right over a tension roller.
8. Turn away the oil pump.

Installation

PERFORMANCE ORDER
1. Replace a sealing ring of the oil pump. A sealing edge and an external surface of a sealing ring slightly oil. Запрессуйте a sealing ring заподлицо.
2. Replace the oil pump only in gathering.
3. A sealing lining of the oil pump replace, the pump put and tighten bolts the moment of 10 Nanometers. At installation of the oil pump watch a pulley of a cranked shaft.
4. Wrap the cleared carving stopper over a tension roller the moment of 45 Nanometers.
5. Tighten a tension roller of a gear belt the moment of 45 Nanometers.
6. Tighten directing roller of a gear belt the moment of 20 Nanometers.
7. Tighten the top and bottom parts of the oil pallet the moment of 10 Nanometers.
8. Establish a gear belt.
9. Establish поликлиновой a belt.
10. Fill in oil, insert the index of level of oil.
11. Execute a control trip and check up the oil pallet on tightness.