Audi 100/A6

1990-1997 of release

Repair and car operation



Audi 100/A6
+ 1. The maintenance instruction
+ 2. Maintenance service
+ 3. Engines
+ 3.2. Diesel engines
+ 3.3. Removal and a partition of engines
+ 4. Cooling system
+ 5. Heating and ventilation
- 6. Fuel system
   - 6.1.2. Technical characteristics
      6.1.3. The air filter and branch pipes of a fence of air
      6.1.4. A regulator of temperature of arriving air
      6.1.5. An accelerator rope
      6.1.6. Elements of system of injection of fuel
      6.1.7. The fuel filter
      6.1.8. The fuel pump and the gauge of level of fuel
      6.1.9. A fuel tank
      6.1.10. Release of pressure from system of injection of fuel
      6.1.11. An inlet collector
      6.1.12. Check of system of injection of fuel
      6.1.13. Neetilirovannyj gasoline
   + 6.2. Multidot system of injection of fuel
   + 6.3. System of injection MPI/MPFI (6-cylinder engines)
   + 6.4. The power supply system of diesel engines
   6.5. The device of service of heating
   6.6. Diagnostics of malfunctions of system of heating
   6.7. The conditioner: not only "pluses", but also "minuses"
   6.8. Rules of service of the conditioner
+ 7. An exhaust system
+ 8. Systems of start, ignition
+ 9. Transmission
+ 10. Brake system
+ 11. Suspension brackets, a steering
+ 12. A body
+ 13. An electric equipment
+ 14. A good advice


6.1.8. The fuel pump and the gauge of level of fuel
THE GENERAL DATA

Elements of a fuel tank

1. A tube of giving of fuel
2. A ventilating hose
3. The ventilating hose going to the coal filter
4. The ventilating valve
5. Fastening
6. The return pipeline
7. Jellied
8. A perepusknaja tube
9. A tube of a jellied mouth
10. An insert
11. A clip

12. A hose
13. A tube of the return pipeline in a fuel tank
14. Dempflernye linings
15. A connection bolt банджо
16. Sealing washers
17. A fixing ring
18. The gauge of level of fuel
19. A sealing ring
20. The fuel pump
21. A fuel tank

Removal

PERFORMANCE ORDER
1. The fuel pump and the gauge of level of fuel are established in a fuel tank.
2. Remove the panel from above a fuel tank.
3. Disconnect a socket of connection of the pump / of the gauge.
4. Disconnect fuel and ventilating hoses, having marked them.
5. Turn off a fixing ring and get the pump / the gauge.
6. Disconnect hoses in the pump and a connection socket.
7. Turn the pump counter-clockwise approximately on 15 mm and remove it from fastening.

Installation

Installation is spent upside-down removals.